Challenge

After updating .NET Runtime components, the Veeam ONE Web Client page fails to load with either of the following errors:

Error Failed to connect to Veeam ONE Server
This page isn't working
<server> is currently unable to handle this request.
HTTP ERROR 500
Failed to connect
Error 500

Cause

These issues may occur after .NET runtime components have been updated, either because the Veeam ONE Reporting Service has not been restarted or because the Veeam ONE Reporting Service is stopped and cannot be started because not all .NET runtime component versions match.

Solution

Check Installed .NET Runtimes

Use the following command to check which versions of the .net runtime components are installed:

dotnet --list-runtimes

Matching .NET Runtime Versions

If all .NET Runtime components are the same version, as shown in the example below, restart the Veeam ONE Reporting Service. The issue should then be resolved. If not, create a case with Veeam Technical Support.

Match
Example of matching .net runtime components.

Mismatched .NET Runtime Versions

If .NET Runtime components are running different versions, update the older ones so all versions match. Then start the Veeam ONE Reporting Service. The issue should then be resolved. If not, create a case with Veeam Technical Support.

mismatched runtime versions
Example of mismatched .net runtime components.
In the mismatched version example above, the solution is to install version 6.0.26 of .NET Desktop Runtime (Microsoft.WindowsDesktop.App) and .NET Runtime (Microsoft.NETCore.App) to match the version of ASP.NET Core Runtime (Microsoft.AspNetCore.App) version.
When .NET runtime components are mismatched, Event 1023 will appear in the Event Viewer's Application log. The Event Properties will describe what components need to be updated and provide a download link to the version required.
Event Log
To submit feedback regarding this article, please click this link: Send Article Feedback
To report a typo on this page, highlight the typo with your mouse and press CTRL + Enter.

Viewing all articles
Browse latest Browse all 4422

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>