Challenge
Veeam ONE Monitor Client cannot connect to Veeam ONE Monitor Server. The following error occurs when you open the Veeam ONE Monitor console:Cause
Under certain circumstances, Veeam ONE Monitor Client cannot establish connection with Veeam ONE Monitor Server.Solution
To resolve the problem, make sure that:-
The name of the machine where Veeam ONE Monitor Server runs is correctly specified in Veeam ONE Monitor client settings.
-
Veeam ONE Monitor Server is reachable via network from the machine where Veeam ONE Monitor Client runs.
-
The user account which is used to run Veeam ONE Monitor Client is included in the Veeam ONE Users security group (at least) on the machine where the Veeam ONE Server component is installed.
-
As per Veeam ONE v6 Release Notes, in multi-Monitor Client environment, connection to Veeam ONE Monitor Server may fail with one of the following errors:
Service connection failed Address = \\IP_Address\pipe\VeeaMDCS Error = 0xe7Service connection failed Address = \\IP_Address\pipe\VeeaMDCS Error = 0x5
To resolve this issue, add the Veeam ONE Monitor Server service account to the Veeam ONE Administrators security group.
- The ports used by Veeam ONE Monitor Client to connect to the Server are getting blocked by firewall. Make sure these ports are open on the firewall:
TCP/445
UDP/137