Quantcast
Channel: Veeam Support Knowledge Base
Viewing all articles
Browse latest Browse all 4362

FC-Only Nimble Array Snapshot Failures in Veeam Backup & Replication P20230718

$
0
0

FC-Only Nimble Array Snapshot Failures in Veeam Backup & Replication P20230718

KB ID: 4478
Product: Veeam Backup & Replication | 12
Published: 2023-08-03
Last Modified: 2023-08-03

Challenge

When using Veeam Backup & Replication 12 P20230718, rescan, backup, and restore operations may fail when the Nimble array is configured to only use Fibre Channel (FC) protocol.

The request could not be understood by the server. Unexpected argument 'multi_initiator'.
error

Solution

A private fix is available for Veeam Backup & Replication 12 P20230718 to resolve this issue; please create a Veeam Support case and mention this KB.

Alternatively, set the Nimble storage protocol setting to "FC and iSCSI" to workaround the issue.

FCandiSCSI
To submit feedback regarding this article, please click this link: Send Article Feedback