Secondary storage backup stops working after NetApp MetroCluster switchover

$
0
0

Challenge

After the MetroCluster switchover a backup job with the SnapVault or SnapMirror specified on the Secondary Target tab cannot update these relationships.

Cause

Unfortunately this is a bug in the OnTap Data Management software. In the event of a switchover Veeam Backup&Replication cannot identify SnapVault/SnapMirror relationships.

Solution

You can trigger manual relationship update with the mandatory -source-snapshot option (for example after switching back to production). In a few minutes the updated relationship appears in the output of zAPI get-destination-iter call.
 

IMPORTANT: there must be at least 1 storage snapshot that wasn’t transferred to the target. If you specify a snapshot in -source-snapshot that was already transferred, such relationship will not appear in the get-destination-iter output. 